Testing Bottled Water

Sept. 10, 2001
Continually Evolving Regulations for D/DBPs

About the author: Barbara L. Marteney and Kristin M. Safran of National Testing Laboratories, Ltd. specialize in consulting with bottled water companies regarding testing requirements. They maintain contacts with bottled water regulators, industry associations and the FDA regarding regulatory changes and bottled water issues. They have authored numerous articles and given presentations regarding state, federal and international bottled water regulations. Marteney and Safran can be reached by phone at 800-458-3330 or 440-449-2525 (Marteney, ext. 217; Safran, ext. 215); [email protected].

undefined

The bottled water industry continues to strive to produce a quality product that inspires consumer confidence.

One of the most important (and sometimes the most complex) area of the bottled water business is compliance with federal, state and industry regulations. As the EPA continues to evaluate contaminants in drinking water for regulation under the Safe Drinking Water Act (SDWA), the FDA must review these regulations for their suitability for bottled water.

On March 28, 2001, the U.S. Food and Drug Administration (FDA) published a Direct Final Rule for Disinfectants and Disinfection Byproducts (D/DBPs) in the Federal Register.

On July 5, 2001, the FDA confirmed the effective date of Jan. 1, 2002, for the D/DBPs final rule. Therefore, bottled water "on the shelf" as of Jan. 1, 2002, must be in compliance with D/DBPs regulations.

The rule establishes allowable levels for the following.

MCL (mg/l)

Residual disinfectants:

Chloramine* 4.0

Chlorine* 4.0

Chlorine Dioxide* 0.8

Disinfection byproducts (DBPs)

Bromate 0.01

Chlorite 1.0

Haloecetic Acids (HAAs) 0.06

The rule also revised allowable levels for the DBPs Total Trihalomethanes (TTHMs) to an MCL of 0.08 mg/l.

In the Federal Register, the FDA states, "FDA recognizes that some bottled water products may be in the marketplace and remain there for two or more years. Thus, there may be some products already in interstate commerce on the effective date that have not been tested under the new part 129 requirements for disinfectants and disinfection by-products and that do not meet the revised standard of quality.

"Under the 403(h)(1) of the Federal Food, Drug and Cosmetic Act (21 U.S.C. 343 (h)(1), such products are considered to be misbranded if they do not meet the revised quality standard for the three residual disinfectants and the four types of DBPs unless they bear a statement of substandard quality. However, FDA believes that it would be appropriate to exercise its enforcement discretion as to those bottled water products that

• Are already in interstate commerce before Jan. 1, 2002,

• Do not meet the revised quality standard for the three residual disinfectants and the four types of DBPs, and

• Do not bear a statement of substandard quality-provided that such products are not adulterated.

Therefore, the agency does not plan to take enforcement action against such bottled water products, provided that such products are safe."

In short, although bottled water on the shelf as of January 1, 2002, would be out of compliance if it does not comply with the bromate MCL, the FDA currently does not intend to take any action such as an off-the-shelf study. If any other organization should decide to perform such a study, non-compliance could result in the need for a recall.

Source Water Requirements

Only sources that are treated with chlorine-based disinfectants or ozone will require testing for DBPs and residual disinfectants. Bottlers using public water supply (PWS) sources and those receiving sources water via disinfected tanker transport also would be required to do this testing.

Frequency of Testing

For 2001, the International Bottled Water Association (IBWA) is requiring quarterly bromate and bromide testing on all types of finished product water and quarterly bromide and chloride testing on all types of source water including municipal sources.

As of Jan. 1, 2002, the FDA will be requiring testing "at least" annually on all types of finished product water and chlorinated or ozonated sources for the D/DBPs. We are waiting clarification on frequency of testing from the FDA.

Some states are expected to require quarterly bromate/bromide monitoring but we are still waiting for more information.

Sources of Contaminants

Bromate can be formed when bromide, a naturally occurring inorganic ion, is exposed to ozone. The conversion of bromide to bromate varies based upon the amount of bromide present, matrix of the water and total concentration/time of ozone exposure (CT Value). The maximum amount of bromate that could be formed can be calculated by multiplying the bromide level present in the raw source by 1.6. Therefore, sources with bromide above 0.0063 mg/l could exceed the allowable limits for bromate.

THMs & HAAs are formed as a result of chlorine disinfections. They are formed when chlorine reacts with organic matter in the water. TTHMs is the sum (in mg/l) of the concentration of the trihalomethane compounds

• Trichloromethane (chloroform),

• Dibromochloromethane,

• Bromodichloromethane, and

• Tribromomethane (bromoform)

Chlorite is a disinfection byproduct that is formed as chlorine dioxide decomposes.

These regulations and recommendations may be subject to change; therefore, bottlers should verify the current requirements with their laboratory representative before ordering any testing.

* Awaiting FDA and state guidance regarding methodology, certification and frequency of testing requirements.

Download: Here

Sponsored Recommendations

Blower Package Integration

March 20, 2024
See how an integrated blower package can save you time, money, and energy, in a wastewater treatment system. With package integration, you have a completely integrated blower ...

Strut Comparison Chart

March 12, 2024
Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Energy Efficient System Design for WWTPs

Feb. 7, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.

Blower Isentropic Efficiency Explained

Feb. 7, 2024
Learn more about isentropic efficiency and specific performance as they relate to blowers.