Municipalities Standardize with Submersible Transducer Technology

Nov. 26, 2007

Municipalities continually face the challenges of building new infrastructure to support growth and keeping existing facilities in proper working order. Although expansion requirements of new housing developments have leveled off with the real estate market, wastewater treatment plants are always in need of maintenance and upgrades.

One particular area that requires trouble-free operation under harsh conditions is pump control in wastewater lift stations. Liquid level measurement in a lift station is an important parameter in operation of the facility. Pump on/off control is regulated by input from level measurement
instrumentation, and this is the critical link where failure can turn a quiet day into a public works nightmare.

Many municipalities are employing hydrostatic measurement technology because it has relatively low acquisition, installation and operating costs. The city of Bend, Ore., is one such municipality, and it is standardizing on hydrostatic level measurement with submersible level transducers at its facilities. With at least 80 lift stations in operation, the city treats more than 1.6 billion gal of wastewater each year.

"The hydrostatic measurement system has proven to be easy to install and trouble-free in operation," said Mark Wolter, electrical supervisor for the city.

This system of measurement typically requires a transducer to be suspended in a vertical PVC pipe in the lift station from which it transmits a 4-20 mA signal to a controller. Because the transducer receives power from the control circuit, it can continuously send data, so a record of levels can be logged.

"We use many transducers throughout our water plant to collect information and data," Wolter said. "When one stops working, we do research to find the most cost-effective replacement to meet our requirements."

Ready for harsh environment

For its application, the city of Bend chose to use a Pressure Systems KPSI model 705 submersible level transducer, which is specifically designed to function in the harsh environment of a lift station. The city benefits from the 705's Teflon-coated, flush-elastomeric diaphragm that resists fouling, and its employees can easily clean the transducer by pulling it up through the
pipe. In addition, because there are no alignment or calibration requirements for reinstallation, downtime is minimized.

Another feature that has proven useful is the 705's on-board lightning protection, which shields it from direct hits and voltage transients that are caused by lightning and can cripple many measurement systems.

"The transducer was recommended to us because of its price, availability and overall functionality," Wolter said. "We chose it because it was the best one for this application, and it has worked out for us."

As with most wastewater treatment challenges, there are many options to consider. Lift station control is one in which maintenance requirements, ease of installation and reliability must be balanced against cost. Hydrostatic level measurement with a submersible transducer has proven to be a good alternative.

Sponsored Recommendations

Get Utility Project Solutions

June 13, 2024
Lightweight, durable fiberglass conduit provides engineering benefits, performance and drives savings for successful utility project outcomes.

Energy Efficient System Design for WWTPs

May 24, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.

Meeting the Demands of Wastewater Treatment Plants

May 24, 2024
KAESER understands the important requirements wastewater treatment plant designers and operators consider when evaluating and selecting blowers and compressed air equipment. In...

Modernize OT Cybersecurity to Mitigate Risk

April 25, 2024
Rockwell Automation supports industry-leading Consumer Packaged Goods company, Church & Dwight, along their industrial cybersecurity journey.